Case 1 | Case 2 | |
Mode | PACV | ACV |
Backup rate | 2 | 0 |
IPAP cmH2O | 13 | 0 |
EPAP cmH2O | 0 | 0 |
Volume guarantee mL | Trigger auto | 1200 |
PACV: pressure-assisted controlled volume; ACV: assisted controlled volume; IPAP: inspiratory positive airway pressure; EPAP: expiratory positive airway pressure.