Abstract
Multidetector computed tomography-generated virtual bronchoscopy (VB) is a recent technical development that allows visualisation of the lumen and wall of the trachea and proximal part of the bronchial tree. A dynamic image is produced that resembles what is seen with fibreoptic bronchoscopy (FB).
Although the technique has not yet reached daily clinical practice and it can never replace FB, performing VB can be useful in well-defined clinical situations.
In this paper, the value and limitations of virtual bronchoscopy will be reviewed, to illustrate the potential role of virtual bronchoscopy in the evaluation of trachea and bronchial tree pathology.
Virtual bronchoscopy (VB) is a novel computed tomography (CT)-based imaging technique that allows a noninvasive intraluminal evaluation of the tracheobronchial tree. Several studies have shown that VB can accurately show the lumen and the diameter of the trachea, the left and right main stem bronchi, and the bronchial tree down to the fourth order of bronchial orifices and branches 1, 2. The morphology of the carinas can be evaluated accurately and the images look very similar to that seen with fibreoptic bronchoscopy (FB).
Although VB is a promising imaging tool, this technique is not currently used in daily clinical practice and more randomised clinical trials are necessary to prove its clinical use. Nevertheless, it seems valuable to review its potential clinical indications. The purpose of this paper is to discuss and illustrate these indications based on VBs generated from the CT scans of a randomly selected group of patients.
Materials and methods
Cases were selected retrospectively and randomly from patients undergoing a multidetector row CT (MDCT) examination of the chest for various reasons. Selection was based on the presence of tracheal and bronchial abnormalities identified on the regular axial images and, when made, on additional coronal and sagittal reconstructions. MDCT was performed on a Phillips 16 slice CT (Philips, Best, the Netherlands). Technical parameters were: Kvp: 120; mAs: 150; collimation: 16*0.75; pitch: 0.9; rotation time: 0.42; slice thickness: 1 mm and an increment of 1 mm. MDCT was either performed with or without IV contrast administration depending on the clinical question. A proprietary virtual endoscopic software program (Endo3D; Philips) was used to reconstruct the CT data into VB images. This software program uses a volume rendering technique. A threshold value between −400 and −600 HU was chosen to evaluate the central bronchial tree. The more distal bronchial tree was evaluated using a threshold of −750 HU.
Endo3D generates a perspective three-dimensional view from the inside of an anatomical structure, such as the inner wall of the colon, trachea or abdominal aorta. This inside-view is generated step by step, creating a film at the end-point. The thickness of each step is 2 mm. The images are orientated with the posterior side at 12 o'clock, the left side at 3 o'clock, the anterior side at 6 o'clock and the right side at 9 o'clock.
The VB films of each patient were studied together with the regular axial CT images and when possible reconstructions in other imaging planes were also performed. VB was also compared with the report of the FB.
Volume rendering and surface rendering are the two techniques that are generally used to interpret volume. Surface rendering needs a surface description, which is extracted from the volume data. Volume rendering directly renders the volume data, without the need for such an intermediate description. Virtual bronchoscopic images are created when a three-dimensional reconstruction, based on these rendering techniques, is strongly enlarged followed by a perspective computation. A computer interpolation is necessary to increase the optical resolution in order to maintain a surface whose appearance is as smooth and as natural as possible. The principal parameter influencing the quality of the reconstruction remains the use of a thin slice thickness 3. A perspective distortion is necessary in order to choose a projection plane representing the frontal opening of the lens in the true bronchoscopy. This perspective distortion results in a more natural appearance of the objects, but is not so good for imaging in general. Defining the diameter can be difficult in the VB 3.
An important parameter for the reconstructions based on the surface or volume rendering technique is the selection of an appropriate threshold above which a surface should be presented as opaque to represent the mucosa. For surface rendering, a specific attenuation coefficient is used to define the air-lumen interface. Depending on the selected attenuation coefficient, surface rendering assigns all structures into air or wall. There is no transition zone. The optimal single attenuation coefficient varies between patients and pathological findings. Surface rendering is sensitive to artefact and noise 4. With volume rendering, the entire spiral CT data set is classified. All pixels are grouped into categories on the base of their attenuation values. These groups are reconstructed as separate structures (air, wall and transition zone). With the existence of this transition zone as a separate structure, volume rendering enhances mucosal detail and adds depth and three-dimensional relief to the images 4.
A single threshold value cannot be used for the imaging of all segments of the tracheobronchial tree. While the value of −520 HU is appropriate for the central bronchial tree, values to −720 HU may be needed for the evaluation of the more distal bronchial tree. An incorrect threshold can produce artefacts like artificial endoluminal masses or openings in the mucosa 5.
The author's experience in reading VB is based on >400 VB performed during the last 6 months and mostly carried out in an experimental set-up, although the CT scans that were the base of the VB for the current study were done in a clinical setting. Recently, the technique was introduced into daily clinical practice and is now used in selected cases, e.g. in the evaluation of the bronchial suture in lung transplant recipients and in patients who cannot undergo FB.
The time necessary to examine the central bronchial tree with VB is ∼15 min. There is no additional cost for the patient, since virtual bronchoscopic imaging is performed using the data from the diagnostic CT.
Evaluation of bronchial stenosis
Hoppe et al. 6 have previously examined whether coronal and sagittal reformations and VB could increase the accuracy of axial CT images to reveal tracheal and bronchial stenosis. These authors found that axial scans had an accuracy of 96%, while accuracy for coronal and sagittal reconstructions was 96 and 96.5%, respectively. When VB was performed accuracy increased to 98% (fig. 1⇓). They also showed that there was a good correlation between VB and FB when the grade of tracheobronchial stenosis resulting from either endoluminal pathology or external impression was estimated. These correlations were also better than when tracheobronchial stenosis was graded on axial slices or on reformatted images 6. This was confirmed by Burke et al. 7 who showed that VB was accurate in assessing width and length of fixed airway lesions. Correlations between FB and VB were excellent when shape and contour of the stenosis were studied, while stenosis-to-lumen ratios were found to be within 10% (sd=8). However, when based on dynamic airway lesions, such as immobile true vocal cords, innominate artery compression and laryngotracheomalacy, VB was unable to detect the cause of airway obstruction 7.
Bronchogenic carcinoma
CT is routinely performed to detect, stage and follow-up primary lung tumours. In most cases only axial CT slices are used for evaluation although with the introduction of newer and faster computers additional two-dimensional and three-dimensional reconstructions are often made to improve the diagnosis, description and staging of these tumours. Finkelstein et al. 8 examined the potential role of VB and found that the sensitivity of VB was 100% for detection of obstructive lesions (figs 2⇓ and 3⇓), and 83% for endoluminal nonobstructive lesions, but the sensitivity for mucosal abnormalities was 0%. The specificity of VB was 100%.
In most cases, VB is able to depict direct tumour signs, such as a tumoral mass, a wall irregularity or a loss of cartilages. Indirect signs, such as stenosis or obstruction, compression or swelling, can often be visualised. However, mucosal infiltration, vascular dilatation and necrosis are usually missed 3.
Rapp-Bernhardt et al. 9 identified endoluminal tumours by VB and grade of the stenosis was calculated and compared with measurements obtained from FB, axial CT slices, multiple plane reconstruction and minimal intension projection reconstructions. No significant differences were found when VB and FB were compared. However, axial CT slices, multi planar reconstructions and minimal intensity projections showed poorer results with over- or underestimation of the stenoses 9.
These preliminary evaluations indicate that VB may be a promising and noninvasive modality for identifying and grading bronchial obstructions and endoluminal lesions. However, VB does not currently enable detection of subtle mucosal lesions and, for this reason, this modality is not appropriate for identifying premalignant lesions in the respiratory tract 8.
In addition, very viscous secretions in the bronchial tree or coagulated blood can mimic a stenosis or occlusion, and only a careful comparison with the axial CT images makes differentiation possible 1. However, excessive smoothing of the airways generated by the computer algorithm can produce false-negatives 10. An important advantage of VB over FB is that axial and, when performed, reformatted images are available. Combining the information from these images allows not only the intraluminal proliferation of the tumour to be appreciated, but also the extraluminal extension of the mass and its relation to the bronchial tree. Another advantage of VB is that the bronchial tree, distal to an obstruction that cannot be passed with FB, can be evaluated 7, 11–13. In this way the length of the stenosis can be estimated, which is of course impossible when the fibreoptic bronchoscope cannot pass the stenosis. VB can also look at the distal border of an endoluminal mass or stenosis by “retroflexing the virtual bronchoscope” 7, 11–13. In contrast to FB, VB is able to visualise the bronchial tree down to the fourth or fifth generation of bronchi. Finally, VB can provide a road map for FB and guide transbronchial biopsy and endobronchial treatment 1.
External compression
VB can be useful to visualise external compressions on the bronchial wall not involving the mucosa (fig. 4⇓). These compressions can be caused by normal anatomical structures (i.e. aortic arch, oesophagus) or can be caused by pathological structures (i.e. extraluminal tumour, enlarged lymph nodes, fibrotic masses). Correlating the position of the virtual bronchoscope with the axial CT images usually allows the exact localisation and cause of the external compression to be defined. However, small compressions are difficult to detect and may be underestimated in 25% of patients 12.
Anatomical malformation and variants
VB may also be used in selected cases to study congenital or acquired anatomical malformations, e.g. tracheal or bronchial diverticula (fig. 5⇓), and tracheal bronchi. These are often incidental findings and treatment is not necessary in most cases. When a detailed study of the malformation is required VB can be performed and can replace the more invasive FB. If the malformation was depicted on a CT examination, no additional radiation to the patient is necessary, since the VB images can be calculated from the existing CT data.
Evaluation of trachea and bronchi in children
Indications for flexible bronchoscopy are, especially in very young children, restricted, because of its invasive character and also owing to the inevitable general anaesthesia. Besides the radiation that usually can be kept to a minimum in children, a VB is less invasive than a FB because a simple sedation is usually sufficient to perform the CT scan. Nevertheless, indications for a VB in children should be defined clearly and individually. The image quality of a VB in neonates is indeed mostly inferior to that in adults because of the smaller diameter of the airways 14. In addition, artefacts due to respiratory motion or mucus plugs can mimic pathology. Respiratory motion is often a problem and is related to the fact that it is usually impossible to perform the examination during one breath hold. Fortunately, new multidetector CT techniques allow very short acquisition times and, in addition, reduce radiation exposure 15. A potential indication for a VB in children is to rule out bronchial abnormalities, such as stenosis (figs 6⇓ and 7⇓) or aberrant bronchi, as a cause of recurrent infiltrates seen on a chest radiograph. Kirchner et al. 16 showed that VB could avoid additional diagnostic bronchoscopy in a high percentage (73%) of cases.
Guidance of transbronchial biopsy
Blind lymph nodal transbronchial biopsies by means of FB do not have high sensitivity. The success rate is 94% for lesions visible during the procedure 17, but only 50% for lymph nodes and tumours that are not visible 15. When the mucosa appears normal, the bioptical sampling can only be approximated. This is the reason false-positives biopsies are very rare, but false-negatives are numerous 17. This delay in staging induces a delay in the start of the chemotherapy, because more invasive staging procedures are necessary 18. Information from VB in combination with axial CT images and coronal or sagittal reconstructions can be helpful in determining the best location for a transbronchial biopsy, especially for lesions that do not affect the mucosa nor distort the airways 18, 19. VB can also help the bronchoscopist define the optimum pathway for passing instruments into lesions beyond the field of view 12, 20, 21. It has been shown that VB significantly increases the success rate of transbronchial biopsy in pretracheal and hilar enlarged lymph nodes and in small (<1.5 cm) lymph nodes 18. However, for subcarinal and aortopulmonary window lymph nodes sampling, this increase was not significant 18. New software programs making the airway wall semitransparent, revealing extrabronchial structures with a perspective view, are promising and can help to identify the lymph nodes adjacent to the trachea and bronchial tree. Research work is also being performed on software for assisted needle aspiration where VB is no longer a passive guide but actively guides the transbronchial biopsy.
Pre- and postoperative assessment
Preoperative planning
VB can be helpful to guide endobronchial procedures, such as laser photocoagulation, brachytherapy, endobronchial cryotherapy and placement of endobronchial stents 11, 19.
VB can provide exact information on luminal diameter and length of stenosis, which is necessary for accurate stent placement (fig. 8⇓) 7, 22. VB and three-dimensional images also provide an easier global understanding of the tracheobronchial status 23 and the relationship with the surrounding normal or pathological structures.
Postoperative evaluation
VB is not only helpful during preoperative staging, but can be used also as a follow-up imaging tool in the postoperative assessment of patients with treatment of the bronchial tree in the evaluation of stenoses, and evaluation of the position and permeability of a stent (fig. 9⇓) 11, 12, 24.
Evaluation of the surgical suture after lung transplantation, lobectomy and pneumectomy is even possible. McAdams et al. 11 showed that VB was slightly more accurate than axial CT for the diagnosis of clinically relevant stenosis at bronchial anastomosis in lung transplant recipients.
Research applications and educational tool
Besides the clinical indications, VB may also be used in educational and research applications, to teach and learn the tracheobronchial anatomy as it appears at bronchoscopy. This “flight simulator” not only helps training pulmonologists to learn how to perform a FB but can also help them, when interpreted immediately before the fibreoptic procedure, to perform this invasive procedure faster and more efficiently 3, 25, 26.
Conclusion
VB is a novel technique for noninvasive evaluation of the tracheobronchial tree. In comparison with real bronchoscopy, VB has the advantage of being a noninvasive procedure that can visualise areas inaccessible to the flexible bronchoscope. Preliminary evaluation indicates that VB may be a promising and noninvasive modality for identifying bronchial obstructions and endoluminal lesions, as well as for assessing the tracheobronchial tree beyond stenoses.
However, VB does not currently enable the detection of subtle mucosal lesions 2, 8. In addition, the patient is exposed to radiation and although VB is accurate 11, 12, 23, 27, it is not 100%. False-positives and false-negatives occur. Feasibility of virtual bronchoscopy also depends on the availability and use of the CT hardware and software, and on the observer's experience 28.
Virtual bronchoscopy will never replace actual bronchoscopy, but in selected cases it can assist and direct fibreoptical bronchoscopy and can sometimes give additional information. It can be expected that in the near future, this technique will be used on a daily basis 3.
- Received September 2, 2003.
- Accepted January 27, 2004.
- © ERS Journals Ltd